![]() ![]() Among these limitations, the most relevant are the use of small samples of subjects used for the validations, the great variability among studies in the light conditions used during the measurements, and the performance of comparative studies between devices, but not considering an intrasession repeatability analysis. Indeed, the scientific literature on validation of pupillometers is scarce and with some limitations. Several devices have been developed to analyse the pupillary function in the clinical practice, but not all of them have been validated. The evaluation of the pupillary function is an indispensable test in some eye examinations, especially in those related to neurological disorders and screening for refractive surgery. The VX120 system can provide consistent measurements of pupil size under scotopic, low mesopic and photopic conditions, with a relative limitation under mesopic conditions. Concerning the comparative analysis between fellow eyes, no statistically significant differences in pupil size were found between right and left eyes in any light condition evaluated ( p ≥ 0.227). The analysis of clinical relevance of differences between pairs (Passing-Bablok) only confirmed the clinical relevance of differences between the first and second repeated measurement of M. However, statistically significant differences were found between repeated measures for M ( p = 0.002) and P ( p = 0.003). No significant differences between these repeated measures were found for S ( p = 0.099) and L ( p = 0.751). Most of differences between repeated measures did not exceed 0.5 mm (82% of S and 100% of P below this value). The level of intrasession variability as well as differences between fellow eyes were evaluated. Likewise, pupil size was also measured once in the fellow eye in a total of 75 eyes. Repeated pupil size measures under photopic (P, 220 lx), mesopic (M, 160 lx), low mesopic (L, 70 lx), and scotopic conditions (S, 1 lx) were obtained with the VX120 system (Visionix-Luneau Technologies, Chartres, France) after a complete eye exam. This prospective study enrolled 100 healthy eyes of 100 patients, with ages ranging from 23 to 65 years old. The aim of this study was to evaluate the intrasession repeatability of pupil size measurements provided by a multidiagnostic platform in a large sample of healthy eyes. If for some reason you can't get the camera on your digital device to work, please follow the steps shown in the video below with the help of a friend.The measurement of the pupillary function is an indispensable test in some eye examinations, being necessary the evaluation of the precision of instruments performing such measures. If your pupil distance (PD) is not written on your prescription, and you cannot obtain this from your Optician (who should have it on file), then please use our online PD measuring tool here: Young Kids Glasses/Goggles: (2 to 5 year olds): 49 mm.Kids Glasses/Goggles: (6 to 9 year olds): 56 mm.Kids Glasses/Goggles (10 to 13 year olds): 60 mm. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |